New Construction HVAC Found Two Tons Undersized — Inlet Beach

The homeowners moved into a brand-new Inlet Beach house and accepted "that's just how beach houses are" for eight months. It wasn't. The system was undersized by over a ton.

UpdatedMay 23, 2026 TypeCase study Page128
Project type Case study
Location Inlet Beach
Scope Field-proven HVAC
Proof Local work
Updated May 23, 2026

The house was eight months old when the owner called. [UPDATE: approximate square footage, e.g. "2,800 square feet"], new construction, Gulf views on two elevations. The AC ran nearly continuously in July and August, never quite reaching setpoint on the hottest days, and the humidity indoors sat uncomfortably high even when the temperature was close. The builder's response when the owner flagged it was: "It's a beach house. They're harder to cool."

That's not wrong, exactly. But it's also the answer a contractor gives when they don't want to look at their own work.

The diagnostic

We ran a Manual J load calculation — the ACCA-standard method for sizing residential HVAC equipment. Manual J accounts for the actual envelope: square footage, ceiling height, window area and orientation, insulation R-values, infiltration rate, internal heat gains, and local design temperatures. It is not a square-footage rule of thumb.

The calculation came back at [UPDATE: calculated load in tons — e.g. "4.2 tons"] for the structure. The installed system was a [UPDATE: installed system size, e.g. "2.5-ton unit"]. That's a [UPDATE: difference, e.g. "1.7-ton"] gap — roughly [UPDATE: percentage undersized, e.g. "68%"] of the required capacity. The system wasn't failing. It was doing everything it could do. It was simply not built for the house.

We also found the refrigerant charge 14% low — a common new-construction issue when the installing contractor doesn't verify charge with gauges after pulling vacuum. And two of the supply runs to the Gulf-facing rooms had visible duct leakage at the boot connections, confirmed with smoke pencil testing.

The correction

We replaced the system with a [UPDATE: correct-sized system installed, e.g. "4-ton Lennox XC20 variable-speed system"], sealed the duct leakage at all boot connections with mastic, and re-balanced the register airflow for the corrected capacity. We pulled the Walton County permit. The new system was commissioned with full refrigerant charge verification, static pressure measurement at the air handler, and room-by-room airflow measurement against the Manual J targets.

The owner's first full summer on the corrected system: setpoint reached within [UPDATE: e.g. "25 minutes"] of startup on the hottest days, indoor humidity consistently below 55%, and energy bills [UPDATE: bill comparison if available].

If you moved into a new Inlet Beach home and the AC has never felt right, it's worth a diagnostic before you spend another summer accepting it. The most common causes are an undersized system, a low refrigerant charge, or duct leakage — all findable and all fixable. Call us.

Ready to get started?

Schedule an Appointment

South Walton & 30A's trusted HVAC specialists — same-day response, no obligation.

4.9 Google Licensed · Insured BBB A+ NATE Certified
Call +1-850-555-0100 — or fill out the form below.
Or provide email below

By submitting this form you agree to our Privacy Policy. We never sell your information.

This is NOT a sign-up nor enrollment in any kind of spam. We typically respond within a day.